The Marine Double-Conversion 1-6 kVA UPS system has been adapted and designed for use on maritime vessels in accordance with strict Maritime IP protocol and all existing security protocols. 1.8 Emergency Power Off – EPO (manual).Ħkva Gamatronic inverter MST Series Online double-conversion UPS - Uninterrupted Power Supply - with static switch call obi 0 or Features Full sine wave inverter Inverter (output) isolation transformer Static switch Volt Frequency Independent (VFI) Alarm dry contacts relay Battery current limit circuit for safe battery charge Rectifier/charger for extended backup time Automatic and manual battery test LED display for status indications load level RS232 interface for Smart Software and SNMP management. Email: Website: 2MUM-PPCN UPS SYSTEM INPUT 3X480 VAC, OUTPUT 3X480 VAC. Batteries are contained in a matching redundant battery cabinet.Gamatronic’s MST is a compact and reliable Double Conversion online UPS system with 6kVA. The UPS is mounted in a 42U x 19" enclosure with a maintenance bypass switch for easy installation. The system can also be configured as a single-phase UPS (120/208 or 120/240 VAC). The load is distributed equally between modules using the Gamatronic Power+ RM100 Active Current Sharing at the Input, Output, and DC bus and enhanced system reliability is provided by the central static switch. System operation is not affected if the controller is removed or inoperable. The high-speed microprocessor based controller uses a unique algorithm that keeps the phase and amplitude of all UPS modules synchronized and identical. The Power+ RM100's system controller provides advanced management and control functions including internet, RS232, TCP/IP, and SNMP communication. Other UPSs connect the batteries via a switch, making the system vulnerable to failure during transfer to backup, as the control system must detect the power outage and initiate the switch from AC input source to battery. The Power+ RM100 is a true online UPS with its batteries galvanically connected directly between the rectifier output and the inverter input on a common DC link. Comprised of one to ten 10kVA/8kW UPS modules, as well as a system controller, a 100kVA static switch, and a distribution block, the system easily grows with your requirements. The Gamatronic Power+ RM100 is a parallel redundant modular UPS capable of scaling from 10kVA to 100kVA.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |